120 ml Urine Collection Container for Vacuum Tube Transfer
In stock
+150€ Península y Baleares
pago
escuelas y universidades
oficiales
| SKU | Product Name | Availability | Price | Qty | |
|---|---|---|---|---|---|
| 408702 | 120 ml PP vacuum bottle, 450 pcs | In stock |
€187.99
|
|
|
| 408702.G | 120 ml PP vacuum bottle, 400 pcs | In stock |
€231.10
|
|
|
| 408726 | Bottle of 120ml in bag individual 350 un. | In stock |
€176.81
|
|
|
| 408726.G | Bottle of 120ml sterile in bag individual 350 un. | In stock |
€208.43
|
|
120 ml Urine Collection Container with Vacuum Tube Transfer
Container for urine collection, containment and transport with integrated direct-transfer system for vacuum tubes. Intended for in vitro diagnostic use in hospital and laboratory settings. Transparent polypropylene construction throughout.
Container and Cap Specifications
- Material: Transparent polypropylene
- Cap: Yellow polyethylene with internal sealing ring
- Transfer system: Cannula with rubber-sheathed inner needle and transparent aspiration nozzle
- Capacity without cap: 145 ml
- Capacity with cap: 120 ml
- Recommended sample volume: 60 ml
- Dimensions: 57 x 73 mm
- Identification: Frosted writing band for permanent marker — fields for Name, No. and Date
Available Versions
- Non-sterile, bulk: Supplied without individual packaging
- Non-sterile, individual bag: Printed bag with directions for use, lot number and expiry date
- Sterile, bulk: Each container labelled with lot number, expiry date and sterilisation method
- Sterile, individual bag: Printed bag with directions for use, lot number, expiry date and sterilisation method
Sample Collection Instructions
- Open the container and place the cap face-up on a flat surface.
- Collect the midstream portion of the urine sample, filling no more than half the container. Discard the initial and final portions of the stream.
- Close the container carefully — do not touch the inner surface of the cap.
- Hand the container to healthcare personnel.
Vacuum Tube Transfer Procedure
- Remove the cap label to expose the cannula.
- Insert the vacuum tube with the stopper facing down.
- Press firmly until the needle pierces the stopper. The tube will aspirate the sample automatically. Repeat for additional tubes as required.
- Remove the tube once aspiration is complete.
- Replace the label over the cannula aperture.
Note: Once the cap is fitted, the volume graduation is affected by the cannula assembly. Vacuum tubes are not included.
| Brand | DELTALAB |
|---|