Handrop® Plus Single-Channel Digital Pipette
In stock
+150€ Península y Baleares
pago
escuelas y universidades
oficiales
| SKU | Product Name | Availability | Price | Qty | |
|---|---|---|---|---|---|
| 770000P | Handrop Plus digital pipette, single-channel, 0.5-10 µl, 1 pc | In stock |
€71.90
|
|
|
| 770005P | Handrop Plus digital pipette, single-channel, 0.1-2.5 µl, 1 pc | Available from 04/01/2027 |
€71.90
|
|
|
| 770040P | Handrop Plus digital pipette, single-channel, 200-1000 µl, 1 pc | In stock |
€71.90
|
|
|
| 770050P | Handrop Plus digital pipette, single-channel, 10-100 µl, 1 pc | In stock |
€71.90
|
|
|
| 770060P | Handrop Plus digital pipette, single-channel, 100-1000 µl, 1 pc | In stock |
€71.90
|
|
|
| 770070P | Handrop Plus digital pipette, single-channel, 20-200 µl, 1 pc | In stock |
€71.90
|
|
|
| 770080P | Handrop Plus digital pipette, single-channel, 2-20 µl, 1 pc | In stock |
€71.90
|
|
|
| 770110P | Handrop Plus digital pipette, single-channel, 1000-5000 µl, 1 pc | In stock |
€71.90
|
|
Handrop® Plus single-channel digital pipette, variable volume 0.1 μl – 5 ml
Variable-volume single-channel electronic pipette with a working range of 0.1 μl to 5 ml. Volume is set through a precision mechanism actuated by the top plunger and read on a lateral digital display. Autoclavable and user-calibratable without returning the instrument to a service centre.
Key features
- Volume range: 0.1 μl to 5 ml
- Volume selection: Precision mechanism, top-plunger actuated
- Display: Lateral digital window for unambiguous volume reading
- Ergonomics: Anatomic body with non-slip grip bands
- Tip ejector: Automatic
- Calibration: User-performable in the laboratory
- Autoclavable: Yes
- Warranty: 1 year
Typical applications
Suited to molecular biology, microbiology, analytical chemistry and quality control laboratories where a wide spread of volumes is handled within a single working day. The 0.1 μl to 5 ml range covers most routine tasks with one instrument. The digital display eliminates the read-off ambiguity inherent in long-stroke mechanical scales.
Maintenance and calibration
Designed for in-house maintenance. Clean the body with ethanol and a lint-free cloth. The tip cone should be wiped regularly. Verify performance every 3 months and after any mechanical intervention.
External repair and calibration service also available—includes a service report and calibration certificate.
Pipetting recommendations
- Keep the pipette vertical during aspiration
- Immerse the tip only a few millimetres into the liquid
- Pre-wet the tip 5 times before dispensing—particularly important with viscous liquids or those with a density different from water
- Pre-wet whenever the liquid temperature differs from ambient
- Control plunger travel with the thumb for consistent, reproducible dispensing
| Brand | DELTALAB |
|---|